High-Quality 10-200KW Diesel Generator Sets from Hichai: Leading Suppliers and Factory in China
| Genset Model | Standby Power | Prime power | Engine Model | Dimension | Weight | ||
|---|---|---|---|---|---|---|---|
| KVA | KW | KVA | KW | mm | KG | ||
| KH-15GF | 22 | 18 | 18.75 | 15 | 4B3.9-G2 | 1160*750*1200 | 800 |
| KH-20GF | 28 | 22 | 25 | 20 | 4B3.9-G2 | 1160*750*1200 | 800 |
| KH-24GF | 33 | 26 | 30 | 24 | 4B3.9-G2 | 1160*750*1200 | 800 |
| KH-32GF | 44 | 35 | 40 | 32 | 4BT3.9-G2 | 1160*750*1200 | 810 |
| KH-48GF | 69 | 55 | 60 | 48 | 4BTA3.9-G2 | 1860*750*1200 | 850 |
| KH-64GF | 83 | 66 | 80 | 64 | 6BT5.9-G2 | 2160*800*1300 | 1040 |
| KH-80GF | 110 | 88 | 100 | 80 | 6BT5.9-G2 | 2160*800*1300 | 1056 |
| KH-92GF | 132 | 106 | 115 | 92 | 6BTA5.9-G2 | 2160*800*1300 | 1096 |
| KH-104GF | 149 | 119 | 130 | 104 | 6BTAA5.9-G2 | 2300*850*1300 | 1400 |
| KH-150GF | 198 | 158 | 187.5 | 150 | 6CTA8.3-G2 | 2400*860*1380 | 1440 |
| KH-180GF | 220 | 176 | 225 | 180 | 6CTAA8.3-G2 | 2500*960*1450 | 1700 |
| KH-200GF | 275 | 220 | 250 | 200 | 6LTAA8.9-G2 | 2640*970*1450 | 2000 |
Component
Frequently Asked Questions
What is the difference between Standby Power and Prime Power?
Standby Power is the maximum power available for emergency use under variable load conditions for the duration of a utility power outage. Prime Power is designed for unlimited running hours annually in variable load applications, serving as the primary source of utility power.
Which engine brands are used in these generator sets?
These generator sets are equipped with high-performance engine models, including the 4B3.9, 4BT3.9, 4BTA3.9, 6BT5.9, 6BTA5.9, 6BTAA5.9, 6CTA8.3, 6CTAA8.3, and 6LTAA8.9 series, which are known globally for their reliability, fuel efficiency, and durable construction.
How do I determine the right generator size for my requirements?
To select the appropriate model, calculate the total wattage of all equipment and appliances you plan to run simultaneously. Ensure the total load does not exceed the Prime Power rating of the generator set, leaving a 10-20% safety margin for startup currents.
Are the dimensions and weights specified in the table for open or silent types?
The dimensions and weights listed in the table correspond to the standard open-type configuration. Silent-type gensets with soundproof canopies will typically have larger dimensions and higher overall weights.
What kind of maintenance schedule do these diesel generators require?
Standard maintenance includes checking oil and coolant levels daily or before every start. Comprehensive maintenance, including changing the engine oil, fuel filters, and air filters, should generally be performed every 250 to 500 operating hours, depending on environmental conditions.